Troubleshooting & repair, Invertec v250-s, Output diodes test (continued) – Lincoln Electric INVERTEC V250-S User Manual

Page 56: Test procedure, Figure f.4 machine output terminals, F-24

Advertising
background image

F-24

TROUBLESHOOTING & REPAIR

F-24

TEST PROCEDURE

1. Remove main input power to the

V250-S.

2. Locate the output terminals on the

front panel of the machine. See
Figure F.4.

3. Remove any output cables and load

from the output terminals.

4. Using the analog ohmmeter test for

more than 200 ohms resistance
between positive and negative out-
put terminals. Positive test lead to
the positive terminal; Negative test
lead to the negative terminal. See
Figure F.5.

NOTE: THE POLARITY OF THE TEST
LEADS IS MOST IMPORTANT. IF
THE TEST LEADS POLARITY IS NOT
CORRECT THE TEST WILL HAVE
ERRONEOUS RESULTS.