F-33

TROUBLESHOOTING & REPAIR

F-33

CONTROL BOARD VOLTAGE TEST (continued)

INVERTEC V250-S

TABLE F.5. Control Board Voltage Test Points.

TEST DESCRIPTION

The 18VAC from the auxil-
iary transformer to the con-
trol board.

Remote trigger circuit test.
(#2 and #4)

Remote trigger circuit test.
(#2 and #4)

Shunt feedback milli-volt
check.

Check for 15VDC control
board supply voltage.

TEST POINTS

Red lead (1J1)

to

Red lead (3J1)

Lead #318 (4J5)

to

Lead #322 (1J5)

Lead #318 (4J5)

to

Lead #322 (1J5)

White lead (2J4)+

to

Black lead (1J4)-

Lead #303 (7J3)+

to

Lead #375 (1J3)-

ACCEPTABLE

VOLTAGES

18VAC

Note: voltage will vary with

input line voltage.

0 VDC.

12VDC.

100 mV.

15VDC.

TEST CONDITIONS

The correct input voltage
applied to the V250-S and
the input power switch (S1)
in the ON position.

When remote trigger circuit
is “closed”.

When remote trigger circuit
is “open”.

Machine loaded to 120
Amps

The correct input voltage
applied to the V250-S and
the input power switch (S1)
in the ON position.