F-58

TROUBLESHOOTING & REPAIR

F-58

PROCEDURE

1. Remove input power to the V250-S.

2. Perform

Filter Capacitor Discharge

Procedure detailed in Maintenance
Section.

3. Locate output diode assembly and

associated leads. See Figure F.17.

4. Cut the necessary wire ties and slide

the sleeving from the four wire con-
nections to be disassembled. See
Figure F.17

5. Label the leads for identification pur-

poses for reassembly.

6. Using the 7/16” wrench remove the

bolts, nuts and washers from two of
the splices.

7. Using the 3/8” wrench and slot head

screwdriver disassemble the other
two splices.

8. Using the 7/16” wrench remove the

bolt and washers connecting the out-
put cable to the diode heat sink. Be
sure to take note of the small resistor
connection at the same point. See
Figure F.17.

9. With the 5/16” nut-driver remove the

two screws from the top rear case
back. See

Figure F.15.

OUTPUT DIODE ASSEMBLY REMOVAL AND REPLACEMENT

(MACHINE CODES BELOW 10150)

(continued)

INVERTEC V250-S

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

SLEEVED SPLICES

SNUBBER RESISTORS

7/16 BOLT

Figure F.17 Output Diode Assembly and Leads