TROUBLESHOOTING & REPAIR

F-55

7. Carefully remove the input rectifier

bridge.

8. When installing a new input rectifier

apply a thin coating of Dow Corning
340 Heat Sink Compound (Lincoln
E1868) to the mating surfaces.
Torque the mounting cap screws
and nuts to 44 IN-LBS.

9. Reconnect the eight leads to the cor-

rect terminals and torque the phillips
head screws to 31 IN-LBS.

INPUT RECTIFIER BRIDGE REMOVAL AND REPLACEMENT (continued)