Page 45: Auxiliary transformer test (continued)

Advertising
background image

F-13

TROUBLESHOOTING & REPAIR

F-13

7. If the correct test voltages are pre-

sent the auxiliary transformer is good.

8. If any of the voltages are missing or

very low, with the proper primary
voltage applied, the auxiliary trans-
former may be faulty. Replace.

9. If the auxiliary transformer tests good

but does not function when connect-
ed to the V250-S check the harness
wiring to the auxiliary transformer.
See wiring diagram.

AUXILIARY TRANSFORMER TEST (continued)

INVERTEC V250-S

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

TEST POINT

TEST POINT

EXPECTED VOLTAGE

H1 (1J7)

H2 (4J7)

200 - 208VAC

H1 (1J7)

H4 (3J7)

380 - 415VAC

H1 (1J7)

H5 (6J7)

440 - 460VAC

RED LEAD (1J1)

RED LEAD (3J1)

18VAC (SECONDARY)

On Control Board

On Control Board

TABLE F.1 Auxiliary Transformer Test Points