C h a p t e r 2

D A 7 U s e r s ’ G u i d e

2

-

2 8

2

DA7 T

our

Monitor B Out

These terminals are 1/4” TRS dual phono plugs at a level of +4dB, 600

BAL,

and connect the output of the

MONITOR B source selection to an external

amplifier for monitoring in the studio.

[REC OUT] Record Output

Use 1/4” TRS phone plugs, at a level of +4dB, 10k

BAL, to output signals for

recording.

Master Output

Female XLR connectors send the

MASTER L/R analog program output to

external speakers and/or a recording device of +4 dB, 600

BAL.

Row 4 Connectors

Remote SW [Switch]

Connect a momentary or press-to-talk remote switch with a 1/4” TS phone
plug for Talk Back or automation record functions. Parameters are assignable
in the

[UTILITY>CONFIG] window.

Digital Input [AES/EBU] [S/PDIF]

An XLR connector inputs an audio signal from a DAT or other digital source.
Assignments can be made from the

[D-I/O>INPUT SET] window. This

incoming source can be monitored by selecting the

2TR A LED button as the

MONITOR A source selection, or, on Channel Faders 15 and 16, when 2TR
A
is assigned in the [D-I/O>INPUT SET] window. The signal can also be
directly assigned to the

MASTER L/R program output.

Digital Record Output [AES/EBU] [S/PDIF]

XLR connections of the

MASTER L/R digital output are for use in recording

by a digital device with AES/EBU digital input capabilities.

Meter Bridge
connector (Option).

MIDI In and Out
connectors

Serial I/O
connectors

Wordclock In and Out
/ Thru connectors

2TR Input Digital (XLR)

Format select switch

Remote switch connector for
Talkback ON/OFF and
automation REC ON/OFF

Cutaway of DA7 Rear Panel Row (4) Digital and Serial Connectors

Record Out Digital(XLR)

RS terminating

switch

Clock terminating &
OUT / Thru switch