Format select switch, Clock terminating 75 ス on/off & out / thru switch, Clock input – Panasonic WR-DA7 User Manual

Page 50: Clock output, Serial terminating switch

Advertising
background image

C h a p t e r 2

D A 7 U s e r s ’ G u i d e

2

-

2 9

2

DA7 T

our

Format Select Switch

This switch is used to select the signal format of the

Digital Record Output,

either

AES/EBU (RS-422/110

) or

S/PDIF (0.5 V[p-p]/ 75

) physically. The

status information included in the output signals is always “professional”
regardless of the switch position.
For S/PDIF usage, an optional adapter is required(Part No. DA/ADPTF). You
must make certain that the adapter connects pin #1 and #3 together.

Clock Terminating 75 ½ ON/OFF & Out / Thru Switch

Located next to the

WORD CLOCK IN BNC connection, this switch should

be set to 75

OFF and Thru position if the DA7 is being used to pass the

wordclock signal to other devices in the chain.

Set the switch to 75

ON and OUT for terminating the wordclock, if the

DA7 is slaved and located at the end of the wordclock chain. The 75

ON

and

OUT position should also be selected when the DA7 is being used to

slave other devices to the DA7’s wordclock. See Chapter 12, D-I/O for more
information.

Clock Input

This is used to synchronize the DA7 to an external wordclock source. This
allows the DA7’s internal clock to slave to another reference, such as a digital
multi-track deck or other device. Use a BNC connector to attach an external
wordclock source.

Clock Output

This is used to slave an external device, such as a digital multi-track machine,
to the DA7 internal clock. It can also be used to relay an external wordclock
that is being used to synchronize the DA7 to an external device. Using a BNC
connector, other devices can synchronize to the DA7 wordclock.

Serial Terminating Switch

Set the switch to

ON if the DA7 is the termination point of the RS-422/485

serial transmission path. The 110

switch turns this function

OFF/ON.