4 code 128, Enabled, Enable ucc/ean-128 – Psion Teklogix Schnellstart- Anleitung 7525 User Manual

Page 148: Enable isbt 128, Decode performance, Decode perf. level, Field size/char

Advertising
background image

Chapter 6: Settings
Code 128

118

Psion Teklogix WORKABOUT PRO With Windows Mobile 2003 SE User Manual

Strip Leading

This parameter determines the number of characters that will be removed from the
beginning of the bar code before the prefix character is added.

Note: For Code 39 bar codes, the “AIAG Strip” is performed before the

“Strip Leading”.

Strip Trailing

The value entered in this parameter determines the number of characters that will be
removed from the end of the bar code before the suffix character is added.

6.20.1.4

Code 128

Enabled

Set this parameter to on to enable “Code 128”.

Enable UCC/EAN-128

EAN/UCC bar codes include group separators and start codes. To successfully scan
this type of bar code, “EAN/UCC 128” must be enabled.

Enable ISBT 128

To successfully scan this variation, “Enable ISBT 128” must be set to on.

Decode Performance

If this parameter is set to on, one of three decode levels assigned to the “Decode
Performance Level” parameter can be selected.

Decode Perf. Level

This parameter provides three levels of decode performance or “aggressiveness” for
Code 128 symbols. Increasing the performance level reduces the amount of required
bar code orientation – this is useful when scanning very long and/or truncated bar
codes. Keep in mind that increased levels reduce decode security.

When you double-tap on this parameter, a dialog box is displayed in which you can
enter a decode performance level of between

1

and

3

.

Field Size/Char

Refer to page 117 for details.