Chapter 10: Specifications
Symagery SX5390 Advanced Imager

312

Psion Teklogix WORKABOUT PRO With Windows Mobile 2003 SE User Manual

Figure 10.3 E1022 Decoded 1D Imager Scanner

10.3.4 Symagery SX5390 Advanced Imager

Storage Temperature

-25 to 70°C (-11 to 160°F)

Humidity

5% to 95% (non-condensing)

Power

Voltage: +5VDC +-5%
Current: 140 mA typical
Standby current: 40µA

Shock

Withstands multiple 1m (3') drops on concrete

Parameter

SX5390

Optical Resolution

1.0 megapixel (1024 x 1024)

Field of View at 6 inches

5.12" x 5.12"

Pitch Angle

±45°

Skew Angle

±45°

Ambient Light

Total darkness to 100,000 lux (full sunlight)

Minimum Contrast

10%

Targeting

Intuitive range finding 626 nm LED

Decode Software Suites and
Symbologies supported

Linear: Code 39; Code 39 Full ASCII; UPC-A, -A2,
-A5; UPC-E, -E2, -E5; EAN-8 -13; JAN; I2of5;
Code 128; Codabar/NW7; RSS 14, RSS Limited,
RSS Expanded, RSS 14 Truncated
PDF417 plus: (as above) + PDF417, microPDF417;
Composite, CC-A, CC-B, CC-C; image capture and
signature capture
Matrix plus: (as above) + Data Matrix; QR Code;
Maxicode; Aztec Code; Planet; Postnet; Royal Mail
4SCC; 4 State postal codes from Australia, Canada,
Japan; Korean Post 3of5

Power supply

3.6 Volt DC nominal (2.7 - 5 Volts DC)
(direct lithium supply)

Operating Temperature

-20° to 50 C (-4 to 122° F)

Relative Humidity

5% to 95% (non-condensing)

Parameter

E1022