Alarm notice, E-mail notice, Panasonic original protocol notice (option) – Panasonic WJ-NT104 User Manual

Page 39: Alarm image readout

Advertising
background image

39

ALARM NOTICE

The WJ-NT104 can notify the user of an alarm event.
The notice is sent either by Panasonic original protocol,
e-mail (SMTP client) or a combination of both.

E-Mail Notice

Mail is sent to the mail server using SMTP (Simple Mail
Transfer Protocol).
16 mail addresses can be specified.

• Mail contents include the URL to access the alarm

image, date and time (hours, minutes, seconds) of
the alarm, camera channel, and connection port
ID.

• If mail is not sent to the mail server before the set

timeout, the mail is automatically deleted.

• In case of continuous recording [after/before], mail

contents are as follows:

[Explanation]

NT104:

Host name set by network setup (8 characters
maximum). Default setting is WJ-NT104.

Date and time of alarm activation:

Based on the time of the internal clock of the
WJ-NT104.

Generating port:

Port number of the alarm input/output terminal
where an alarm is generated

Link to alarm image:

Alarm image URL. In continuous recording
mode, the URL of the first image. In the follow-
ing cases, accessing the URL may not display
the alarm image.

q Alarm image is overwritten.

(For the number of alarm images recorded see
page 38.)

w Alarm log is overwritten.

(Up to 100 alarm logs can be recorded.)

e NT104 is restarted due to a change in settings.
r Power is switched back on or the reset button

is pressed.
Number of frames recorded:

Number of alarm images to be recorded.
None in case Single Frame Recording
mode.

[Example]

If the PC on the alarm receiving end does not respond
after a specified number of connection retries because it
is not powered up or for some other reason, the WJ-
NT104 sends the alarm notice to another PC registered
as an alarm notice recipient.

Note

Panasonic Original Protocol Notice
(option)

This is a special protocol based on the TCP/IP protocol
used to notify the users of an alarm.
If an alarm is activated, an alarm notice is sent to the
PC IP addresses set for the WJ-NT104 as alarm notice
recipients.

• To receive alarms, you need to install the special

alarm receiving software for the WJ-NT104 (option)
on your PC. Your PC must be kept powered up
and connected to the WJ-NT104 via a LAN.

• Up to 16 alarm notice destinations can be speci-

fied for the WJ-NT104.

Alarm Image Readout

Recorded alarm images can be read out by accessing
the alarm list (almindex.html) of the WJ-NT104.

!!! ALARM NOTICE !!!

Source

: 133. 185. 10. 47 (NT104)

Port

: PI0 5ch

Date

: Jul/04/99

Link

: http://133. 185. 10. 47/ALM0001_00.JPG

<NUMBER OF FRAMES RECORDED>
Total

: 14

Before

: 4

After

: 10

Advertising