Utility software, Network setup, Connection – Panasonic WJ-NT104 User Manual

Page 54

Advertising
background image

54

UTILITY SOFTWARE

Network Setup

For the network setup, you need to set the IP address
using the Utility Software provided and connect the WJ-
NT104 to a PC via the RS-232C port.

Connection

The COM1 port of the RS-232C interface is used for
setting the IP address. Your PC should be IBM-PC
compatible, have Windows95, Windows98 or Windows
NT4.0 installed, and have an RS-232C port.
Before installing the Utility Software provided, read the
Readme.txt file on Utility Software disc.

q Connect the RS-232C port on the front of the WJ-NT104

and the RS-232C port of the PC with an RS-232C
cable.

w Set bits #7 and #9 of the MODE selector to ON position

(leave the others on OFF), and then press the RESET
button on the front of the WJ-NT104.

e Click the

Start

button, point to

Programs

and then

WJ-

NT104 Utilities

, then click

Network Configuration

.

r To set the IP address: Enter the IP address into the

[IP

ADDRESS]

fields of the dialog box, then click the

[SET]

button. If the IP address has been set properly,

the response command REI and the IP address enter-
ed (in hexadecimal, 8-bit notation, e.g., REI:COA8000A
for IP address 192.168.0.10) should appear in the WJ-

NT104 RESPONSE

field. If a wrong number is shown,

click the

[SET]

button again.

t To set the netmask: Enter a set value into the

[NET-

MASK]

fields of the dialog box, then click the

[SET]

button. If the netmask has been set properly, the
response command REM and the set value entered (in
hexadecimal, 8-bit notation, e.g., REM:FFFFFF00 for
the set value 255.255.255.0) should appear in the WJ-

NT104 RESPONSE

field. If a wrong number is shown,

click the

[SET]

button again.

y To set the default gateway: Enter a set value into the

[DEFAULT GATEWAY]

fields of the dialog box, then

click the

[SET]

button. If the default gateway has been

set properly, the response command REG and the set
value entered (in hexadecimal, 8-bit notation, e.g.,
REG:COA80001 for the set value 192.168.0.1) should
appear in the

WJ-NT104 RESPONSE

field. If a wrong

number is shown, click the

[SET]

button again.

u Complete the setup by clicking the

[EXIT]

button.

i Return all switches on the MODE selector to OFF posi-

tion and then press the RESET button on the front of the
WJ-NT104.
This completes setup and return to the normal applica-
tion mode.

PC

RS-232C cable

WJ-NT104

9-pin D-sub connector

(female)

9-pin D-sub connector

(female)

1

2

3

4

5

6

7

8

Frame

1

2

3

4

5

6

7

8

Frame

Shield

Advertising