DATE/TIME mode:

added digits (month, date, hour,

minute, second, and last 2-digit year).
Added MMDDhhmmsssYY (for example,
0123134500 101 for January 23 13:45:00.1, 2001)
SEQUENTIAL NUMBER(MAX FIXED) mode: added
number 00001 to 65535 automatically.
SEQUENTIAL NUMBER(MAX VARIABLE) mode:
added number between 00001 to max.(your setting
number till 65535).
Is disabled to specify over 65535.

i

TRANSFER INTERVAL

Specify the interval time for uploading the data periodi-
cally.

Valid Value: seconds: between 0.2 and 1 with 0.1

increment
between 1 and 3600 with 1
increment

minutes:

between 1 and 1440

For examples: 1min and 30sec: set 90 sec.

2 hours:

set 120 min.

Notes:

• It is disabled to specify the time in combination

with the minutes and seconds.

• It may occur that uploading is disabled with the

specified duration through the line status.

o

FTP CHANNEL SELECT

You can specify the input channel for uploading when
the multi input selection mode is set in the MODE
SETUP window.

ON:

Enables uploading.

OFF:

Disables uploading.

The factory defaults are OFF.

Alarm Setup

!0

FTP ON/OFF

Selects to enable or disable alarm image upload with
the FTP when an alarm is received.

ON:

Enables alarm upload.

OFF:

Disables alarm upload.

The factory default is ON.

!1

TARGET DIRECTORY

Specifies the absolute path for the directory of the FTP
server when uploading the alarm images.

Note:

There are 3 alarm recording modes available,

Single Frame, Continuous (post-images), and
Continuous (pre and post-images) recording. It is
enabled to specify the directory of FTP server for
normal and alarm status, and store the uploading
images separately.

!2

ALARM IMAGE FILE NAME SETUP

Enter the desired image file name in the box.
The file name consists of

x

(image file name)✽✽✽✽✽✽.

jpg

x:

camera CH number (1 – 4)

FIXED mode:

Only the image file name, no addition

✽✽✽✽✽✽.

DATE/TIME mode:

added digits (month, date, hour,

minute, second, and last 2-digit year).
Added MMDDhhmmsssYY (for example,
0123134500101 for January 23 13:45:00.1, 2001)

SEQUENTIAL NUMBER(MAX FIXED) mode:

added

number 00001 to 65535 automatically.

SEQUENTIAL NUMBER(MAX VARIABLE) mode:

added number between 00001 to max.(your setting
number till 65535).
Is disabled to specify over 65535.

Note:

This FTP client function can support the FTP

server such as Windows 2000, Windows NT, Free
BSD, Turbolinux, and Red Hat Linux.