<Interface circuit inside the unit>

5V

5V

10k

22k

Input
terminal

0.047

µ

F

GND

POWER ON/POWER OFF/
ALARM IN/REC/CLOCK ADJ
Input terminal
• Input Circuit

<Interface circuit inside the unit>

Output terminal

GND terminal

ALARM OUT/MODE OUT Output terminal
• Output Circuit

Using POWER ON terminal

POWER ON
terminal

ground

0V

power off

Unit's
power

DC 5V OUT
(4.5-5.5V
Max.30mA)

DC 5V

power on

power on

shut down

boot

up

Using POWER OFF terminal

POWER OFF
terminal

0V

power off

ground

shut down

power on

Unit's
power

DC 5V OUT
(4.5-5.5V
Max.30mA)

DC 5V

<Interface circuit inside the unit>

5V

5V

10k

22k

Input
terminal

0.047

µ

F

GND

POWER ON/POWER OFF/
ALARM IN/REC/CLOCK ADJ
Input terminal
• Input Circuit

Figure 7. Schematics for Alarm Input and Output Terminals

3.

Optional. Connect the recorder to a remote source for turning the unit on/off.

By using the POWER ON/POWER OFF terminals, it is possible to turn on/off the
recorder externally. The POWER ON terminal turns power on or off (refer to Figure 8).
The POWER OFF terminal turns power off (refer to Figure 8). Turning the recorder on/off
also controls the output of the DC 5V OUT terminal (refer to Figure 8). Figure 9 shows
the schematic for the POWER ON/POWER OFF terminals.

Figure 8. Operation of Power On and Power Off Terminals

Figure 9. Schematic for Power On and Power Off Terminals

4.

Optional. Connect equipment to the CLOCK ADJ, REC, MODE OUT, and CALL OUT
terminals. Refer to Figure 10 for schematics of the input/output terminals.

The CLOCK ADJ input terminal is used for adjusting the clock. The input is active
when a ground or low voltage signal is applied. The input is non-active when the termi-
nal is open.