Scsi cable peripheral copy/archive device, Scsi terminal, Scsi cable – Pelco DX3000 User Manual

Page 16

Advertising
background image

Pelco Manual C681M-D (2/02)

15

CLOCK ADJ

REC

POWER ON

POWER OFF

ALARM OUT

MODE OUT

CALL OUT

CALL OUT GND

DC 5V OUT

MAX 30mA

RS-232C

1 2 3 4 5 6 7 8 9

ALARM IN

RESET

ON

OFF

SCSI

TERMINATION

SCSI cable

Peripheral
copy/archive
device

Terminator

GND

GND

GND

GND

GND

SCSI

terminal

1

2

3

4

5

6

7

8

9

1

2

3

4

CAMERA IN

CAMERA OUT

5

6

7

8

9

Y/C

OUT

VIDEO

SCSI

MIC

IN

OUT

AUDIO

01147

CLOCK ADJ

REC

POWER ON

POWER OFF

ALARM OUT

MODE OUT

CALL OUT

CALL OUT GND

DC 5V OUT

MAX 30mA

1 2 3 4 5 6 7 8 9

ALARM IN

RESET

ON

OFF

SCSI

SCSI

TERMINATION

SCSI cable

SCSI cable

Peripheral
hard disk
drives

Terminator

SCSI cable

GND

GND

GND

GND

GND

SCSI

terminal

MIC

IN

OUT

AUDIO

RS-232C

1

2

3

4

5

6

7

8

9

1

2

3

4

CAMERA IN

CAMERA OUT

5

6

7

8

9

Y/C

OUT

VIDEO

011487

5.

Optional. Connect peripheral recording devices.

By connecting peripheral recording devices to the recorder through the SCSI interface
(SCSI-II half-pitch 50-pin), storage space can be increased and archiving and copying
functions can be performed.

To increase storage space, up to two (DX3009-060, DX3016-060, and DX3016-120)
or three (DX3009-030) peripheral hard disk drives (maximum of 34 GB per unit for
DX3009 models or 103 GB per unit for DX3016 models) can be added to supplement
the built-in hard disk.

For archiving or copying functions, a tape or disk device can be connected.

The following tape devices can be connected to the recorder:

Pelco

DX3000-D25 (drive)

Pelco

DX3000-T25 (blank tape)

The following disk devices can be connected to the recorder:

MO (640 MB)

Fujitsu SMB-640WF

MO (1.3 GB)

Fujitsu SMB-1300W

DVD-RAM

Panasonic LF-D200JD

HDD

SCSI-IF Type

Zip (250 MB)

IOMEGA Z250S

Connections between the recorder and peripheral devices are made with SCSI cables
(not supplied). As SCSI cables differ with each device, check for the appropriate pin
arrangement before use. Cables must not exceed 3 feet (1 m).

On the rear panel of the recorder is a SCSI termination switch. Set the switch ON
when nothing is connected the SCSI connector. Set to OFF when connecting periph-
eral devices.

Correct termination is necessary to maintain proper electrical connections to the pe-
ripheral devices. Make sure that the last peripheral device is terminated. (Depending
on the device, the terminator may be built into the device. In this case, set the built-in
terminator correctly.) Use an active terminator for SCSI.

Set the SCSI ID number of the peripheral recording device. Refer to the operation
manual of each peripheral recording device for setting the SCSI ID Number. Use ID1-3
for hard drives, ID4 for an archive device, and ID5 for a copy device. On DX3016 mod-
els, also use ID4 when a hard disk drive is connected for repeated backup recording
(considered an archiving function).

Figure 12. Connecting Peripheral Recording Devices (DX3009 Models Shown)