Pelco DX3000 User Manual
Page 84
Pelco Manual C681M-D (2/02)
83
Inputs/Outputs
POWER ON:
Input for power ON. Low input state is power off; high input
state is power on.
POWER OFF:
Input for power OFF. Low input state is power off.
ALARM IN (1-9):
Inputs for starting alarm recording. Active: When terminals
are short-circuited or “Low” Level voltage is applied.
Non active: Open.
CLOCK ADJ:
Input for adjusting clock. Active: When terminals are short-
circuited or “Low” Level voltage is applied. Non active: Open.
REC:
Input to start recording. Active: When terminals are short-
circuited or “Low” Level voltage is applied. Non active: Open.
GND:
Ground.
ALARM OUT:
Output for use while alarm recording is under way.
Active: “Low” Level. Maximum drive current: 7 mA DC.
MODE OUT:
Output for indication of selected recording mode.
Non-active: Open. Maximum voltage: +24V DC.
DC 5V OUT:
Output for DC 5V OUT.
CALL OUT:
Output for external warning device. Active: ON. Maximum
drive current: 7 mA DC.
CALL OUT GROUND:
Ground for external warning device. Non active: Open.
Maximum voltage: +24VDC.
GENERAL
Operating Temperature:
41
°
to 104
°
F (5
°
to 40
°
C).
Relative Humidity:
Maximum 80%
Dimensions:
16.7 (W) x 15.0 (D) x 4.45 (H) inches
(42.5 x 38.0 x 11.3 cm)
Unit Weight
DX3009 models:
15.7 lb (7.1 kg)
DX3016 models:
17.9 lb (8.1 kg)
Connectors
Push-in terminal:
POWER ON, POWER OFF, ALARM IN, CLOCK ADJ, REC
inputs
Ground, CALL OUT ground
ALARM OUT, MODE OUT, DC 5V OUT, CALL OUT outputs
BNC:
Video input/output
SVHS:
Video output
DB9:
RS-232C for connection with personal computer
50-pin D-type:
SCSI