2 automatic radio address, Direct tcp connections for tekterm, Direct tcp check duplicate terminal number – Psion Teklogix 9160 G2 User Manual

Page 263

Advertising
background image

Psion Teklogix 9160 G2 Wireless Gateway User Manual

241

Chapter 22: The 9160 G2 As Base Station

Radio Link Features Configuration Settings

tocol Terminal Timeout is 60, and this parameter is set to 75%, then the timeout
would be 60 min x 75% = 45 minutes.

An offline terminal is still considered part of the system. Messages to offline termi-
nals are queued at the 9160 G2. The terminal remains offline until it transmits an
online message. Values for this parameter range from 50 to 90.

Direct TCP Connections for TekTerm

Enabling this parameter allows the TekTerm program resident in Psion Teklogix
terminals to connect directly to the 9160 G2, when it is acting as a base station to
a host via TCP/IP.

Direct TCP Check Duplicate Terminal Number

When this parameter is enabled, the 9160 G2 will reject Direct TCP terminals which
try to connect using a terminal number already in use by another terminal. When
disabled, the most recent terminal to connect will take precedence over the other ter-
minals using the same terminal number.

22.4.3.2

Automatic Radio Address

Each Psion Teklogix terminal using the radio link has a unique radio address number,
which can be assigned automatically by the 9160 G2 by enabling this parameter.

To enable this parameter, the values for the first and last radio address numbers
must lie between 1 and 3840. The default values for the range are 1024 ... 2084.
To disable the parameter, set the values to 0.

Notes: When enabling this parameter:

1. Direct TCP Connections for TekTerm must be disabled (see page

241).

2. The Auto ID parameter in the terminal must be enabled in order for

the radio address to be automatically assigned.

Advertising