Field descriptions – Perle Systems IOLAN SCS User Manual

Page 246

Advertising
background image

Channels

246

IOLAN SDS/SCS/STS User’s Guide, Version 3.6

Field Descriptions

Configure the following parameters:

Description

Provide a description of the channel, making it easier to identify.

Data Options: Maximum 20 characters, including spaces

Input Mode

When selected, the channel will be reading the status of the line (input). The
internal jumpers must match the software configuration; the internal jumpers
are factory configured for

Input Mode

.

Default: Input Mode

Latch

Latches (remembers) the activity transition (active to inactive or inactive to
active).

Data Options: None, Inactive-to-Active, Active-to-Inactive

Default: None

Invert Signal

When enabled, inverts the actual condition of the I/O signal in the status;
therefore, an inactive status will be displayed as active.

Default: Disabled

Trigger

When the trigger condition is met, triggers the specified alarm action.

Data Options:

z

Disabled—No alarm settings. This is the default.

z

Inactive—When the expected Digital input is active, going inactive will
trigger an alarm.

z

Active—When the expected Digital input is inactive, going active will
trigger an alarm.

Default: Disabled