Planet Technology SGSD-1022 User Manual

Page 337

Advertising
background image

User’s Manual of SGSD-1022 / SGSD-1022P

SGSW-2840 / SGSW-2840P

337

The page includes the following fields:

Object

Description

Power limit mode

Allow to configure power limit mode of Web Smart Device. It can choose :

„

Port Priority Deliver PoE power by port priority setting

„

Total Limit. Set limit value of the total POE port provided power to the PDs.

Power reservation

Show the total watts usage of PoE Switch.

PoE Function

Can enable or disable the PoE function.

Priority

Set port priority for the POE power management

It can choose the “port priority”, value is “1~4”. High priority is “1”.

Device class

Class 0 is the default for PDs. However, to improve power management at the

PSE, the PD may opt to provide a signature for Class 1 to 3.

The PD is classified based on power. The classification of the PD is the maximum

power that the PD will draw across all input voltages and operational modes. A

PD shall return Class 0 to 3 in accordance with the maximum power draw as

specified by Table 4.1.

Current(mA)

It shows the PoE device current Amp.

Consumption [W]

It shows the PoE device current watt.

Power Limit

It can limit the port PoE supply watts.

Per port maximum value must less 15.4, total ports values must less than the

Power Reservation value.

Once power overload detected, the port will auto shut down and keep on

detection mode until PD’s power consumption lower than the power limit value.

For SGSW-2840P, the total PoE power reservation from Port-1~24 is up to 260W

For SGSD-1022, the total PoE power reservation from Port-1~8 is up to 110W

„

PD Classifications

A PD may be classified by the PSE based on the classification information provided by the PD. The intent of PD classification is

to provide information about the maximum power required by the PD during operation. Class 0 is the default for PDs. However,

to improve power management at the PSE, the PD may opt to provide a signature for Class 1 to 3.

The PD is classified based on power. The classification of the PD is the maximum power that the PD will draw across all input

voltages and operational modes.

A PD shall return Class 0 to 3 in accordance with the maximum power draw as specified by

Table 4-13-1.

Advertising