Fault messages, No control – RoboteQ AX2850 User Manual

Page 105

Advertising
background image

AX2550 Motor Controller User’s Manual

105

Fault Messages

Fault Messages

The AX2550 uses the LED display to report fault conditions. When these messages are
displayed, the motors are normally stopped.

No Control

This message is displayed in the R/C mode to indicate that no valid radio signal has been
detected at its inputs or that radio signal has been lost. When the controller is configured
in the mixed mode, signals on channel 1 and channel 2 must be present to enable the con-
troller. When the controller is configured in the separate mode, a signal received on either
channel will enable the controller. When enabled, the controller will display the normal
motor status described previously.

The “no control” message is displayed using the following sequence of digits.

Forward

Reversed

Reversed

Reversed

MOSFET Transistors are

OFF

Motors are freewheeling

Signals a temporary Off condition in

case of Overvoltage, undervoltage or

Overtemperature condition (see

page 38), of if Dead-man switch is

activated (see page 52)

Rapidly Flashing

MOSFET Transistors are

OFF

Motors are freewheeling

Controller is permanently Off after an

Encoder Error, Short Circuit detection

or Emergency Stop activation. Con-

troller must be restarted.

TABLE 18. Motor Commands and resulting display

Possible Display

Motor 1

Motor 2

Comment

Advertising