Controller powering schemes, Powering the controller from a single battery – RoboteQ AX2850 User Manual

Page 32

Advertising
background image

Connecting Power and Motors to the Controller

32

AX2550 Motor Controller User’s Manual

Version 1.9b. June 1, 2007

All 3 ground (-) are connected to each other inside the controller. The two main battery
wires are also connected to each other internally. However, you must never assume that
connecting one wire of a given battery potential will eliminate the need to connect the
other.

Controller Powering Schemes

Powering the Controller from a single Battery

The diagram on Figure 12 show how to wire the controller to a single battery circuit and
how to turn power On and Off.

Connect the two thick black wires to the minus (-) terminal of the battery that will be used
to power the motors. Connect the two thick red wires to the plus (+) terminal of the bat-
tery. The motor battery may be of 12 to 40 Volts.

10.5V to 40V

0V

Controller is On.

Power Stage is Off

10.5V to 40V

1V to 40V

Controller is On.

Power Stage is Active

TABLE 3. Controller Status depending on Power Control and VMot

Power Control input is
connected to

And Main Battery
Voltage is

Action

12V to 24V

Motor Battery

Power on/off

switch

Optional

Emergency
Disconnect

-

+

+

-

Motor1

Motor2

Controller

Fuse

VMot

VMot

M1+

M1

-

V

Con

GND

GND

GND

M2+

M2-

FIGURE 10. Powering the AX2550 from a single battery

Notes:

-

The Battery Power connection are doubled in order to provide the maximum current to the controller. If
only one motor is used, only one set of motor power cables needs to be connected.

-

Typically, 1, 2 or 3 x 12V batteries are connected in series to reach 12V, 24V or 36V respectively.