Important notice, Input control mode, Motor control mode – RoboteQ AX2850 User Manual

Page 145

Advertising
background image

AX2550 Motor Controller User’s Manual

145

Accessing & Changing Configuration Parameter in Flash

These parameters are stored in the controller’s Flash memory and are not intended to be
changed at runtime.

Important Notice

The above parameters are stored in the MCU’s configuration flash. Their storage is perma-
nent even after the controller is powered off. However, because of the finite number of
times flash memories can be reprogrammed (approx. 1000 times), these parameters are
not meant to be changed regularly, or on-the-fly.

All parameters in Flash (except for the Amps calibration) are reset to their default
values every time new firmware is loaded into the controller.

Input Control Mode

Address:

^00

Access:

Read/Write

Effective:

After Reset

This parameter selects the method the controller uses for accepting commands

Motor Control Mode

Address:

^01

Access:

Read/Write

Effective:

After Reset or ^FF

^1D

Joystick Max 2 LS

Instant

^F0

Amps Calibration Parameter 1

Reset

^F1

Amps Calibration Parameter 2

Reset

Value

Mode

See pages

0

R/C Radio mode (default)

page 109

1

RS232, no watchdog

page 109

2

RS232, with watchdog

3

Analog mode

page 123

TABLE 25. Configuration parameters in Flash

Location

Description Active

after

Advertising