Amps limit – RoboteQ AX2850 User Manual

Page 146

Advertising
background image

Serial (RS-232) Controls and Operation

146

AX2550 Motor Controller User’s Manual

Version 1.9b. June 1, 2007

This parameters selects the various open loop and closed loop operating modes as well as
the feedback method.

Amps Limit

Address:

^02

Access:

Read/Write

Effective:

After Reset or ^FF

This parameter configures the controller’s Amps limit. Note that this limits the amps flow-

ing out of the power supply. Current flowing through the motors may be higher.

Bit

Definition

See pages

2:0

Motor Control Mode

0 = A & B separate speed open loop
(default)

1 = A & B mixed speed open loop

2 = A speed open loop, B position

3 = A & B position

4 = A & B separate speed closed loop

5 = A & B mixed speed closed loop

6 = A speed close loop, B position

page 42

page 97

page 85

6:3

Reserved

6

Ch1 Feedback type

0 = Analog

1 = Encoder

page 97

page 85

7

Ch2 Feedback type

0 = Analog

1 = Encoder

Bit

Definition

See pages

3:0

Coarse Amps

0 = 30A

1 = 45A

2 = 60A

3 = 75A

4 = 90A

5 = 105A (default)

6 = 120A

page 44

7:4

Fine Amps

Substract this number from the Coarse
Amps value

Advertising