Connecting the controller to your pc using roborun – RoboteQ AX2850 User Manual

Page 22

Advertising
background image

AX2550 Quick Start

22

AX2550 Motor Controller User’s Manual

Version 1.9b. June 1, 2007

Connecting the controller to your PC using Roborun

Connecting the controller to your PC is not necessary for basic R/C operation. However, it
is a very simple procedure that is useful for the following purposes:

to Read and Set the programmable parameters with a user-friendly graphical inter-
face

to obtain the controller’s software revision and date

to send precise commands to the motors

to read and plot real-time current consumption value

Save captured parameters onto disk for later analysis

to update the controller’s software

Restart

Press & hold Prog

Press and hold the Prog button for 10 seconds while
resetting or powering on the controller

After 10 seconds, the controller will enter the program-
ming mode and flash alternatively the current parame-
ter (I= Input Mode) and its value (0= R/C mode).

Program mode entered

after 10 seconds

Press the Prog button to move to the next parameter
(C= Motor Control Mode) and its value (0= Separate)

Press Prog to select

next parameter

Press the Set button to change the parameter’s value
(1= Combined)

Press Set to select

next value for parameter

Press the Prog button record the change and move to
the next parameter (A= Amps limit) and it’s value (2=
75A)

Press the Reset button or power off/on the control to
restart the controller using the new parameters.

Press Prog to store change

and select next parameter

Reset controller

to exit

Advertising