Using the Roborun Configuration Utility

190

AX2550 Motor Controller User’s Manual

Version 1.9b. June 1, 2007

line of the save file contains the Header names. Each following line contains a complete
set of parameters. The Header name, order and parameter definition is shown in Table 36:

Connecting a Joystick

Exercising the motors can easily be done using a Joystick in addition to the on-screen slid-
ers. Simply connect a joystick to the PC and enable it by clicking in the Joystick check box
in the PC utility.

If the box is grayed out, the joystick is not properly installed in the PC. Click on the “Config
Joystick” button to open a configuration screen and the joystick control panel.

Joystick movement should automatically translate into Channel 1 and Channel 2 command
values and make the sliders move. These commands are also sent to the controller. In the
Config Joystick panel, the Joystick may be configured so that the X-Y channels are
swapped and the direction for each axis reversed.

It is strongly recommended that an USB rather than Analog joystick be used.

TABLE 36. Logged parameters order, type and definition

Parameter Header

Data type/range

Measured Parameter

Seconds

Integer

Timer value expressed in seconds

Command1

-127 to +127

Command applied to channel 1

Command2

-127 to +127

Command applied to channel 2

Power1

0 to 127

Amount of power applied to the output stage of chan-
nel 1

Power2

0 to 127

Same for channel 2

Ana 1, Speed 1, Pos 1

or Temp 1

or Volt 1

-127 to + 127

-40 to +150

0 to 55

Value of sensor connected on analog input 1. Data is
automatically converted to the right value and format
by Roborun according to the sensor that is being used.

Ana 2, Speed 2, Pos 2

Temp 2 or

Volt 2

-127 to + 127

-40 to +150

0 to 55

Same for channel 2

Amps1

0 to 255

Measured Amps on channel 1

Amps2

0 to 255

Measured Amps on channel 2

FET Temp1

-40 to +150

Measured Temperature on channel 1’s heatsink.

FET Temp2

-40 to +150

Measured Temperature on channel 2’s heatsink.

Batt Volt

0 to 55

Main Battery Voltage.

Ctrl Volt

0 to 28.5

Internal 12V Voltage.

Enc1

-127 to + 127

Measured Optical Encoder’s Speed or Position
depending on selected operating mode

Enc2

-127 to + 127

Same for channel 2

Advertising