Data logging in r/c mode – RoboteQ AX2850 User Manual

Page 121

Advertising
background image

AX2550 Motor Controller User’s Manual

121

Data Logging in R/C Mode

Data Logging in R/C Mode

While in R/C Mode, the AX2550 will continuously send a string of characters on the RS232
output line. This string will contain 12 two-digit hexadecimal numbers representing the fol-
lowing operating parameters.

Captured R/C Command 1 and 2

Power Applied to Controller’s output stage

Values applied to Analog inputs 1 and 2

Amps on channel 1 and 2

Internal Heat Sink temperatures 1 and 2

Main Battery voltage

Internal 12V voltage

Encoder Speed or Position feedback, if encoder module is present.

The entire string is repeated every 200 milliseconds with the latest internal parameter val-
ues. This information can be logged using the Roborun Utility (see “Viewing and Logging
Data in Analog and R/C Modes” on page 192
). It may also be stored in a PDA that can be
placed in the mobile robot.

The string and data format is described in “Analog and R/C Modes Data Logging String For-
mat” on page 166.
The serial port’s output can be safely ignored if it is not required in the
application.

To read the output string while operating the controller with the R/C radio, you must mod-
ify the R/C cable to add an RS232 output wire and connector that will be connected to the
PC’s communication port. Figure 82 and below shows the wiring diagram of the modified
R/C cable for connection to a PC.

Output C

ON

Output C
OFF

Output C
OFF

FIGURE 81. Using Channel 3 to activate accessory outputs

Advertising