Updating the controller’s software, Important warning – RoboteQ AX2850 User Manual

Page 194

Advertising
background image

Using the Roborun Configuration Utility

194

AX2550 Motor Controller User’s Manual

Version 1.9b. June 1, 2007

Note that it is not possible to use this configuration to change the controller’s parameters
or update the controller’s software.

Updating the Controller’s Software

The AX2550’s operating software can be easily upgraded after it has left the factory. This
feature makes it possible to add new features and enhance existing ones from time to
time.

Important Warning

Updating the controller will cause all its parameters to reset to their default condi-
tions. You should re-enter these parameters to the desired value prior to re-installing
and using the controller.

The upgrade procedure is quick, easy and error proof:

1-

Connect the controller to the PC via the provided RS232 cable.

2- Apply a 12V to 40V power supply to the controller’s Ground and Power Control input

(thin black and yellow wires). Leave VMot disconnected.

3- Launch the Roborun utility if it is not already running. Then click on the “Update Con-

troller Software” button.

4- If the controller is On, Roborun will find it and prompt the selection of the new soft-

ware file. It may happen that the controller is not responding properly and you may be
asked to reset it while connected.

5- Press

the

“Program” button to start programming. Do not interrupt or cut the

power to the controller while the new program is loading into Flash memory.

6- After a verification, you will be notified that the operation was successful and you will

see the new software revision and date as reported by the controller.