Left / right tuning adjustment – RoboteQ AX2850 User Manual

Page 49

Advertising
background image

AX2550 Motor Controller User’s Manual

49

Left / Right Tuning Adjustment

The AX2550 is delivered with the “linear” curves selected for both joystick channels. To
select different curves, the user will need to change the values of “E” (channel 1) and “F
(channel 2) according to the table below. Refer to the chapter “Configuring the Controller
using the Switches” on page 171
or “Using the Roborun Configuration Utility” on page 177
for instructions on how to program parameters into the controller.

Left / Right Tuning Adjustment

By design, DC motors will run more efficiently in one direction than the other. In most situ-
ations this is not noticeable. In others, however, it can be an inconvenience. When operat-
ing in open loop speed control, the AX2550 can be configured to correct the speed in one
direction versus the other by as much as 10%. Unlike the Joystick center trimming tab that

TABLE 7. Exponent selection table

Exponentiation Parameter Value

Selected Curve

E or F = 0

Linear (no exponentiation) - default value

E or F = 1

strong exponential

E or F = 2

normal exponential

E or F = 3

normal logarithmic

E or F = 4

strong logarithmic

20

40

60

80

100

0

20

40

60

80

100

- 20

- 40

- 60

- 80

- 100

20

40

60

80

100

% Forward
(Motor Output)

Logarithmic Strong

Logarithmic Weak

Linear (default)

Exponential Weak

Exponential Strong

% Reverse

% Command Input

Deadband

FIGURE 21. Exponentiation curves

Advertising