O P E R A T I O N S

Setting Output Format

350-7951

Quadra User’s Guide

30

.

. .

.

.

2.

To enable automatic detection and loading of a display timing set type
the following command (using upper or lower case characters).

H OPREF EDID

Enter

This will cause Quadra to read the preferred timing parameters from
your display device, and then search for a match in the Factory
Timing List
. If it finds a match (for example, one that you have
previously stored), it selects and loads those parameters.

If Quadra does not find a match in the “user entry” section, it searches
through all factory defined entries and loads the closest match.

These steps should be repeated for each of the Quadra output channels (1 - 4).
this command enables you to set the output display parameters, using values
that are stored in the system’s

Factory Timing List

.”

MANUALLY

LOADING OUTPUT

. . . . . . . . .

PARAMETERS

Use the following steps if you want to manually enter your own output
parameters:

1.

Ensure that the display(s) that you want to set up are connected to
selected Quadra outputs.

2.

Obtain a copy of the display device’s operations manual or technical
guide, and make a note of the following parameters: monitor type,
format (analog or digital), resolution, refresh rate, sync, sync polarity
and interlace.

3.

To enable manual loading of a display timing set type the following
command (using upper or lower case characters).

H OPREF INT

Enter

4.

Using the command line interface, request help text for the command.
Using upper or lowercase characters, type:

H OPTMLOAD

Enter

This action displays the command’s parameters and arguments in the
command window.

Figure 3-3.

Help Text — Output Timing Load Command

5.

Show the timing list. Type:

TMLIST

Enter