C O M M A N D L I N E I N T E R F A C E

Command Summary

350-7951

Quadra User’s Guide

76

.

. .

.

.

SETTINGSEXPORT

[TIMING | WINDOW |
SYSTEM | ALL]
[filename]

This command enables you to store

Quadra

settings on an external computer. This is useful in
backing up settings, or providing the ability to
“clone” the settings on multiple

Quadra

devices.

Storing this data is a two step process:

Create a text file named “export.txt
that is stored in

Quadra

memory

.

Upload this file to your PC.

Please note the following important rules:

You can specify your own filename
using the optional filename argument.

To save timing, window (display) and
system parameters together, use the

ALL

option. Issuing the command

without an argument also accomplishes
this.

Alternatively you can save just the
individual

TIMING

,

WINDOW

or

SYSTEM

parameters.

To save only the user defined timing
values, use the

TIMING

argument.

If you wish to save only the window
preset parameters for each active
window preset, use the

WINDOW

argument.

If you wish to save only the system parameters for
the current system settings, use the

SYSTEM

argument. Note that this does not include the
settings saved in the

SAVECONFIGguration

register.

Use the following procedure to save your settings:

Create the file using the

SETTINGSEXPORT

command from

the Telnet or serial port.

Log in to the FTP server in

Quadra

.

Enter the user name “

rgb

” (lower case)

and the password “

spectrum

.”

Use the FTP command “get export.txt
to move the file from

Quadra

to your

PC.

Type “close” to log off the FTP server.