O P E R A T I O N S

Testing Outputs

350-7951

Quadra User’s Guide

31

.

. .

.

.

6.

Review the list in detail, and note the timing parameters that most
closely match the specifications of your monitor.

7.

Load the timing parameters for the selected output. Type:

OPTMLOAD <output #> <register #>

Enter

8.

Verify that the parameters are loaded by querying the command and
the output. Type:

OPTM <output #>

Enter

9.

Repeat from step 1 to set up additional outputs.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

T E S T I N G O U T P U T S

This section provides instructions for using the “

TestPattern

” command. For a

selected output channel, you can enable a variety of internal test patterns and
quickly check your Quadra’s outputs.

Use the following steps to test each output:

1.

Ensure that the display(s) that you want to test are connected to
Quadra outputs, and that their output formats have been set as outlined
in the

Setting Output Format

” section.

2.

Request help text for the command. Type:

H TP

Enter

This action displays the command’s parameters and variables.

Figure 3-4.

Help Text — Test Pattern Command

3.

To test a single output, type:

TP <output #> [test pattern]

Enter

S

Example: To display color bars on output 2, type:

TP 2 BARS

Enter

4.

To test all outputs, type:

TP ALL [test pattern]

Enter

S

Example: To display the grid on all outputs, type:

Advertising