RTNE[5:0]: Sets RTNE in combination with PCDIVH and PCDIVL to decide the number of DOTCLK in
1H (1 line) period according to the following formula. RTNE is enabled when RGB interface is selected.

DOTCLKD x RTNE (Number of clock) ≤ DOTCLK in 1H period.

Table 32 DOTCLKD in 1H period (RGB interface operation)

RTNE[5:0]

Clocks per

line period (1H)

RTNE[5:0]

Clocks per

line period (1H)

6'h00

Setting inhibited

6'h20

32 clocks

6'h01 Setting

inhibited

6'h21

33

clocks

6'h02

Setting inhibited

6'h22

34 clocks

6'h03 Setting

inhibited

6'h23

35

clocks

6'h04

Setting inhibited

6'h24

36 clocks

6'h05 Setting

inhibited

6'h25

37

clocks

6'h06

Setting inhibited

6'h26

38 clocks

6'h07 Setting

inhibited

6'h27

39

clocks

6'h08

Setting inhibited

6'h28

40 clocks

6'h09 Setting

inhibited

6'h29

41

clocks

6'h0A

Setting inhibited

6'h2A

42 clocks

6'h0B Setting

inhibited

6'h2B

43

clocks

6'h0C

Setting inhibited

6'h2C

44 clocks

6'h0D Setting

inhibited

6'h2D

45

clocks

6'h0E

Setting inhibited

6'h2E

46 clocks

6'h0F Setting

inhibited

6'h2F

47

clocks

6'h10

16 clocks

6'h30

48 clocks

6'h11

17 clocks

6'h31

49 clocks

6'h12

18 clocks

6'h32

50 clocks

6'h13

19 clocks

6'h33

51 clocks

6'h14

20 clocks

6'h34

52 clocks

6'h15

21 clocks

6'h35

53 clocks

6'h16

22 clocks

6'h36

54 clocks

6'h17

23 clocks

6'h37

55 clocks

6'h18

24 clocks

6'h38

56 clocks

6'h19

25 clocks

6'h39

57 clocks

6'h1A

26 clocks

6'h3A

58 clocks

6'h1B

27 clocks

6'h3B

59 clocks

6'h1C

28 clocks

6'h3C

60 clocks

6'h1D

29 clocks

6'h3D

61 clocks

6'h1E

30 clocks

6'h3E

62 clocks

6'h1F

31 clocks

6'h3F

63 clocks