Renesas R61509V User Manual

Page 68

Advertising
background image

R61509V

Target

Spec

Rev. 0.11 April 25, 2008, page 68 of 181

BT[2:0]: Sets the factor used in the step-up circuits. Select the optimal step-up factor for the operating
voltage. To reduce power consumption, set a smaller factor.

Table 41 Step-Up Factor for Step-Up Circuits

BT[2:0] DDVDH

VCL VGH

VGL

3’h0 Setting

inhibited

3’h1

-(VCI1+DDVDH x 2)
[x –5]

3’h2

-(DDVDH x 2)
[x –4]

3’h3

VCI1 x2
[x 2]

-VCI1
[x –1]

DDVDH x 3

[x 6]

-(VCI1+DDVDH)
[x –3]

3’h4 Setting

inhibited

3’h5

-(VCI1+DDVDH x 2)
[x –5]

3’h6

-(DDVDH x 2)
[x –4]

3’h7

VCI1 x2
[x 2]

-VCI1
[x –1]

VCI1+DDVDH

x 2

[x 5]

-(VCI1+DDVDH)
[x –3]

Notes: 1. The factors in the brackets show the step-up factors from VCI1.

2. Make sure DDVDH=max.6.0V, VGH=max.18.0V, VGL=max -13.5V, VGH-VGL=max. 28.0V, and

VCL=max -3.0V.