3-8

Section 3

SETUP

ZS-MDC

User’s Manual

Section 3
About Setup

TEACH Mode
In this mode, the measured value is displayed at all times on the main display. The
threshold values are displayed on the sub-display. Which of the HIGH or LOW threshold
values is displayed changes according to the setting of the threshold selector switch.

Key Operations

↑ UP key
↓ DOWN key

↑ UP key: Executes trigger input.
↓ DOWN key: Executes reset
input.

The function changes depend-
ing on the settings.
• Changes numerical values.
• Changes text.

MENU key

Displays the display customize
menu.

Returns to the top of the display
customize menu.

SET key

Executes a zero reset.

Applies numerical value settings.

ESC key

Hold down for at least two sec-
onds to cancel a zero reset.

Returns to the previous menu.
When the top menu is displayed,
returns to the measured value
display.

Key

TEACHING

DIRECT IN

Function keys

Not used

Not used

LEFT key

→ RIGHT key

Not used

Selects the digit in the threshold
numerical value.

↑ UP key
↓ DOWN key

Not used

Changes the threshold numerical
value.

MENU key

Registers the measured value
when this key is pressed as the
threshold value.

Not used

SET key

Not used

Applies the newly set threshold
value.

ESC key

Not used

Cancels the newly set threshold
value.

Key

Measured Value Display

Display Customize Menu

Displayed alternately

TEACH MODE
MENU : TEACHING

TEACH MODE
: DIRECT IN