Omron ZS-MDC User Manual

Page 62

Advertising
background image

4-6

Sect

ion 4

APPLICATION SETTING EX

AMPLE

S

ZS-MDC

User’s Manual

Section 4
Measuring the Relative Difference between Steps

[SENSING]-[CALC]-[CALC]-[STEP]

3.

Set the expression of TASK1.

INPUT X: INPUT A
INPUT Y: INPUT B

4.

Following the same procedure as 2 to 3, set
up TASK2.

INPUT X: INPUT B
INPUT Y: INPUT C

5.

Following the same procedure as 2 to 3, set
up TASK3.

INPUT X: INPUT C
INPUT Y: INPUT A

• To output the judgment result of the operation

[I/O SET]-[I/O SET]-[OUT]

6.

Select TASK1, TASK2, or TASK3 depending
on the details to be output.

To output judgment on the difference between
point A and point B: Set TASK1 to I/O SET
To output judgment on the difference between
point B and point C: Set TASK2 to I/O SET
To output judgment on the difference between
point C and point A: Set TASK3 to I/O SET

1

INPUT X

2

INPUT Y

Input A

Input B

Input C

Y X

Input A

Input B

Input C

X

Y

Input A

Input B

Input C

Y

X

1

TASK1

3

TASK3

2

TASK2

4

TASK4