Sect

ion 4

APPLICATION SETTING EX

AMPLE

S

Section 4

Measuring the Warp of a Workpiece

4-17

ZS-MDC

User’s Manual

Measuring the Warp of a Workpiece

In the example below, the difference between the points on both edges (input A point and
input C point) of the workpiece, the average distance value, and the measured value (input
B point) of the center is taken to be the warp amount. Expression: Z=B- (A+C)/2. In the
actual setting, calculation mode “K+mX+nY” is used.

For details on how to connect and install the Sensor Heads and Sensor Controllers, refer to the “ZS-L
User’s Manual”.

FUN Mode-[SENSING]-[SEL CH]

1.

Assign the CH No. of the controller to inputs
A to C to be used for the expression.

INPUT A:1CH
INPUT B:2CH
INPUT C:3CH

Input A

Input B

Input C

CH0

CH1

CH2

CH3

Input A Input B Input C

The operation and/or measurement results are output
as judgement output or linear output.

1

INPUT A

3

INPUT C

2

INPUT B