Setting assignments – Omron ZS-MDC User Manual

Page 52

Advertising
background image

3-14

Section 3

SETUP

ZS-MDC

User’s Manual

Section 3
Setting the Sensor Controller to Obtain Sensing Information from

Setting the Sensor Controller to Obtain Sensing Information from

Set which gang-mounted Sensor Controller to obtain information from, and which logic
operations are to be performed on that information.

Setting Assignments

Assign the channel to perform logic operation on.

FUNMode-[SENSING]-[SEL CH]

Setting

Description

INPUT A (input A)

Assigns the target Sensor Controller to input A.
Range: None, 1CH onwards (largest CH of gang-mounted Sensor Controllers)

(default: 1CH. Note that range becomes “None” if 1CH does not exist.)

INPUT B (input B)

Assigns the target Sensor Controller to input B.
Range: None, 1CH onwards (largest CH of gang-mounted Sensor Controllers)

(default: 2CH. Note that range becomes “None” if 2CH does not exist.)

INPUT C (input C)

Assigns the target Sensor Controller to input C.
Range: None, 1CH onwards (largest CH of gang-mounted Sensor Controllers)

(default: 3CH. Note that range becomes“None” if 3CH does not exist.)

INPUT D (input D)

Assigns the target Sensor Controller to input D.
Range: None, 1CH onwards (largest CH of gang-mounted Sensor Controllers)

(default: 4CH. Note that range becomes “None” if 4CH does not exist.)

INPUT E (input E)

Assigns the target Sensor Controller to input E.
Range: None, 1CH onwards (largest CH of gang-mounted Sensor Controllers)

(default: 5CH. Note that range becomes “None” if 5CH does not exist.)

INPUT F (input F)

Assigns the target Sensor Controller to input F.
Range: None, 1CH onwards (largest CH of gang-mounted Sensor Controllers)

(default: 6CH. Note that range becomes “None” if 6CH does not exist.)

INPUT G (input G)

Assigns the target Sensor Controller to input G.
Range: None, 1CH onwards (largest CH of gang-mounted Sensor Controllers)

(default: 7CH. Note that range becomes “None” if 7CH does not exist.)

INPUT H (input H)

Assigns the target Sensor Controller to input H.
Range: None, 1CH onwards (largest CH of gang-mounted Sensor Controllers)

(default: 8CH. Note that range becomes “None” if 8CH does not exist.)

INPUT I (input I)

Assigns the target Sensor Controller to input I.
Range: None, 1CH onwards (largest CH of gang-mounted Sensor Controllers)

(default: 9CH. Note that range becomes “None” if 9CH does not exist.)