Mt. Vernon Pellet Stove (AE)

G. Pipe Selection Chart

Do NOT pack insulation or other combustibles between

firestops.
• ALWAYS maintain specified clearances around venting

and firestop systems.

• Install firestops as specified.
Failure to keep insulation or other material away from vent

pipe may cause fire.

Figure 13.1

3 in. or 4 in. (76mm or 102mm) Diameter Pipe

Equivalent Pipe

Length In Feet

ALTITUDE IN THOUSANDS OF FEET

0

20

30

1 2 3 4 5 6 7 8 9 10

4 in. (102mm) Diameter Pipe Only

10

Example 1

Example 

Example 1

: If the equivalent length of pipe is  feet (.58m) with alti-

tude of 8,000 feet (0m) you must use  inch (10mm) diameter type

“L” or “PL” vent.
Example 2

: If the equivalent length of pipe is 1 feet (.0m) with altitude

of 6,000 feet (15m) you may use  or  inch (76 to 10mm) diameter

type “L” or “PL” vent.

The chart will help you in determining proper venting size

according to the equivalent feet of pipe calculated previously

and the altitude above sea level of this installation.
Figure 13.1.

a. Locate the calculated equivalent feet of pipe on the verti-

cal left side of the chart.

b. Move to the right horizontally on the chart until you reach

your altitude above sea level.

c. If you fall below the diagonal line,  or  inch (76 to

10mm) pipe may be used.

d. If it is anywhere above the diagonal line, a  inch (10mm)

diameter pipe is required.

NOTICE:
• A 90° elbow is 5 times as restrictive to the flow of exhaust

gases under positive pressure as 1 foot (05mm) of hori-

zontal pipe.

• A foot of horizontal pipe is twice as restrictive as a foot of

vertical pipe.