Page 

7034-106F

August 13, 2009

R

Mt. Vernon Pellet Stove (AE)

R

R

1

Listing and Code Approvals

A. Appliance Certification

E. BTU & Efficiency Specifications

Model

Mt. Vernon Pellet Stove AE

Laboratory

OMNI Test Laboratories, Inc.

Report No.

061-S-68-6

Type

Solid Fuel Room Heater/Pellet Fuel
BurningType

Standard

ASTM E1509-0, ULC S67-00 and

ULC/ORD-C18-M1990 Room Heater

Pellet Fuel Burning type and (UM) 8-

HUD, Mobile Home Approved.

FCC

Complies with Part 15 of FCC Rules.

Operation is subject to the following

two conditions: (1) this device may not

cause harmful interference, and () this

device must accept any interference

received, including interference that

may cause undesired operation.

Emissions Rating:

EPA Compliance

*BTU Output:

1,60 - 60,00 / hr

Efficiency:

81.4% - 83.6%

Heating Capacity:

,00 - ,800 square feet depend-

ing on climate zone

Hopper Capacity:

81 lbs

Fuels:

Pellets, Shelled Field Corn, Wheat

and Black Sunflower Seeds

Shipping Weight:

9 lbs

C. Glass Specifications

This appliance is equipped with 5mm ceramic glass. Replace

glass only with 5mm ceramic glass. Please contact your

dealer for replacement glass.

This appliance is approved for mobile home installations

when not installed in a sleeping room and when an outside

combustion air inlet is used.
The structural integrity of the mobile home floor, ceiling, and

walls must be maintained.
The appliance must be properly grounded to the frame of

the mobile home and use only Listed pellet vent Class “L”

or “PL” connector pipe.
A Quadra-Fire Outside Air Kit must be installed in a mobile

home installation. You must order the Outside Air Kit sepa-

rately.

B. Mobile Home Approved

NOTICE:

This installation must conform with local codes.

In the absence of local codes you must comply with the
ASTM E1509-04, ULC S627-00, (UM) 84-HUD and
ULC/ORD-C-1482.

D. Electrical Rating

115 VAC, 60 Hz, Start 5 Amps, Run 1.5 Amps

NOTICE:

Hearth & Home Technologies, manufacturer

of this appliance, reserves the right to alter its prod-

ucts, their specifications and/or price without notice.

Quadra-Fire is a registered trademark

of Hearth & Home Technologies.

WARNING! Risk of Fire! Hearth & Home Technologies dis-
claims any responsibility for, and the warranty and agency
listing will be voided by the above actions.
DO NOT:

• Install or operate damaged appliance

• Modify appliance

• Install other than as instructed by Hearth & Home

Technologies

• Operate the appliance without fully assembling all

components

• Overfire

• Install any component not approved by Hearth &

Home Technologies

• Install parts or components not Listed or approved.

Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.

For assistance or additional information, consult a qualified
installer, service agency or your dealer.

Note: The appliance is also approved for installation
into a shop.

*BTU will vary, depending on the type of fuel you use in

your appliance. Consult your Quadra-Fire dealer for best

results.