Troubleshooting, Mt. vernon pellet stove (ae) – Quadra-Fire MTVERNON-AE-MBK User Manual

Page 32

Advertising
background image

Page 

7034-106F

August 13, 2009

R

Mt. Vernon Pellet Stove (AE)

R

R

9

Troubleshooting

With proper installation, operation, and maintenance your appliance will provide years of

trouble-free service. If you do experience a problem, this troubleshooting guide will assist a

qualified service person in the diagnosis of a problem and the corrective action to be taken.

This troubleshooting guide can only be used by a qualified service technician.

Error Message

Possible Cause

Corrective Action

Bad wall control or control board

 wires have loose connections or installed

wrong

Replace wall control or control board

Check connections

BAD TC DROP TUBE
(TC = Thermocouple)

Drop tube thermocouple is broken or leads are

reversed

Check connections
Replace thermocouple

BAD TC FIREPOT
(TC = Thermocouple)

Firepot thermocouple is broken or leads are

reversed

Check connections
Replace thermocouple

SNAP DISC TRIPPED

Overheat sensor (snap disc) has tripped

Convection blower may need cleaning

Turn power off to appliance and manually

reset snap disc then turn power back on
Clean convection blower if needed

VACUUM SW ERROR
(SW = Switch)

Vacuum switch is bad

Vacuum hose is plugged/disconnected

Check connections. Bypass vacuum with

jumper wire, if runs, switch is bad. Replace

switch
Check vacuum hose

COMB BLOWER JAMMED

Combustion blower is blocked/jammed

Remove blockage
Replace blower if necessary
Must unplug appliance to clear error

AUGER JAMMED

Auger jammed, feed motor bad

Pull the feed system and inspect
Clear jam and Press Retry

MISSED IGNITION

Igniter bad or poor harness connection
Out of fuel or fuel is bridging in hopper
Faulty firepot thermocouple connection has

shorted.

Check connections, if OK replace igniter
Break up bridging pellets. Refill hopper
Replace the thermocouple

Press Retry

MIN FIREPOT TEMP

Out of fuel

Refill hopper
Add handful of pellets to firepot to prime it
Press Retry

MAX DROP TUBE TEMP

Appliance in over-heat condition
Flame height set too high
Components may need cleaning

Confirm setting matches burning fuel
Adjust flame height
Clean the firebox, heat exchanger, convec-

tion blower, firepot and ash pan

CONV BLOWER JAMMED

Convection blower blocked/jammed

Remove blockage
Replace blower if necessary
Must unplug appliance to clear error

CHECK ASHPAN

Auto-clean jammed

Auto-clean switch is bad
Linkage has become disconnected

If ashpan is empty, check for a jam. Use a

screw driver and firmly push in the firepot

floor holes and flex spring and push toward

home to release jam
Replace switch
Reconnect linkage

SCREEN GOES BLANK

Static discharge or nearby lightning or
Electric fast transients at the input mains

Wait 5 seconds and press any key to

refresh the screen.

Hopper lid not closed all the way
Switch is out of adjustment (auger will not

function)

Close the lid. If that didn’t work replace the

switch
Adjust or replace switch

Firebox door is not latched properly

Adjust or replace door switch

Out of fuel

Check the fuel level, if OK the switch may be

out, replace switch