Page 8

7034-106F

August 13, 2009

R

Mt. Vernon Pellet Stove (AE)

R

R

5. Auto-Clean Cycle
The firepot auto-clean system will cycle:
• W

hen the appliance is first plugged in

• W

hen the house reaches temperature and the appliance

shuts down

• At prescribed intervals, depending on the type of fuel se-

lected

• When starting up after an electrical interruption
If your appliance is running and the auto-clean cycle is initi-

ated, the appliance will revert to shutdown cycle.

The floor of the firepot will open and dump the ash into

the ash pan

It takes approximately  minutes to complete the auto-

clean cycle

• The floor will then shut, and if the thermostat is still call-

ing for heat, the fire will start again

• During this auto-clean cycle, the convection blower may

continue to run. The combustion blower will continue to

run.

Additional Screen Messages:

READY

It is telling you that the home is up to temperature

and doesn’t need any heat.

- - - - -

The screen will show 5 dashes when the wall

control and the control board are NOT communicating with

each other. Check that the wiring on the thermostat is prop-

erly connected.
MAINTENANCE BURN

This indicates the appliance is

operating on battery backup, prior to the auto-clean. The

maintenance burn will keep the system from shutting down

as the appliance will not automatically re-light in battery

back-up mode.
OFF

The AUTO/MANUAL SETTING screen has been set

to OFF. Set the appliance to OFF when performing periodic

maintenance to prevent an unexpected startup.
BLANK SCREEN

The ON/OFF switch may be in OFF

position. Turn to ON position.

WARNING

Fire Risk

Do NOT operate appliance:

• With appliance door open.

• With firepot floor open.

Do NOT store fuel:

• Closer than required clearances to com-

bustibles to appliance.

• Within space required for loading or ash

removal.