Maintaining & servicing your appliance – Quadra-Fire MTVERNON-AE-MBK User Manual

Page 33

Advertising
background image

R

R

R

August 13, 2009

7034-106F

Page 

Mt. Vernon Pellet Stove (AE)

10

Maintaining & Servicing Your Appliance

CAUTION! SHOCK AND SMOKE HAZARD!
• Proper Shutdown Procedure must be followed.

• Smoke spillage into room can occur if appliance is not

cool before unplugging appliance.

• Risk of shock if appliance is not turned off before servic-

ing appliance.

A. Proper Shutdown Procedure

1. Set wall control to OFF on AUTOMATIC / MANUAL SET-

TING screen. Figure 33.1.

. Wall control screen will scroll through the following mes-

sages after setting to OFF.

• Shutdown

• Auto-Clean

• Off

Before Servicing Your Appliance

Manual

O

ff

Automatic

Figure 33.1

B. Quick Reference Maintenance Chart

NOTICE: These are recommendations. Clean more frequently if you encounter heavy

build-up of ash at the recommended interval or you see soot coming from the

vent. Not properly cleaning your appliance on a regular basis will void your
warranty
.

. Smoke spillage into the room can occur if the appliance

is not cool before unplugging.

. There is a risk of shock if the appliance is not unplugged

before servicing the appliance.

After servicing, restart with the AUTO/MANUAL SETTINGS

screen. Figure 33.1.

Follow the detailed instructions found in this

section for each step listed in the chart below.

Cleaning or Inspection

Frequency

Daily Weekly

Every 2

Weeks

Monthly

Yearly

Ash Pan - Burning Wood Pellets

Every 5 bags of fuel

OR

X

Ash Pan - Burning Alternate Fuels

Every 1 bag of fuel

OR

X

Ash Removal from Firebox

More frequently depending on the

fuel type or ash build-up

OR

X

Auto-Clean Inspection

More frequently depending on the

fuel type

OR

X

Blower, Combustion (Exhaust)

More frequently depending on the

fuel type

OR

X

Blower, Convection

More frequently depending on the

fuel type

OR

X

Door Latch Inspection

Prior to heating season

OR

X

Firebox - Prepare for Non-Burn Season At end of heating season

OR

X

Firepot - Burning Softwood Pellets

Every 5 bags

OR

X

Firepot - Burning Hardwood Pellets

Every  bags

OR

X

Firepot - Burning Alternate Fuels

Every 1 bag

OR

X

Glass

When clear view of firepot

becomes obscured

OR

X

Heat Exchanger & Drop Tube

Every 1 ton of fuel

OR

X

Hopper

Every 1 ton of fuel or when chang-

ing fuel types

OR

X

Venting System

More frequently depending on the

fuel type

OR

X