Mt. vernon pellet stove (ae) – Quadra-Fire MTVERNON-AE-MBK User Manual

Page 43

Advertising
background image

R

R

R

August 13, 2009

7034-106F

Page 

Mt. Vernon Pellet Stove (AE)

17. Power Supply
The power supply is located at the rear of the appliance. It

converts 10 volt AC current to 15 volt DC current to power

the appliance.
18. Overheat Sensor (Snap Disc)
The overheat sensor is mounted on the back of the drop

tube in the center of the appliance and has a reset button.

To access it remove the right side panel. If the fire tries to

burn back into the feed system or push exhaust up the feed

tube, this sensor will shut the appliance down, however the

wall control will still display messages. This sensor must be

manually re-set. Disconnect power before resetting.
19. Thermocouple - Firepot

This thermocouple is located on top of the firepot inside

the thermocouple cover (ceramic protection tube). The

thermocouple sends a millivolt signal to the control board

telling the control board there is a fire in the firepot.
20. Thermocouple - Drop Tube
This thermocouple is located on the bottom of the drop

tube on the right side and attached with a wing nut. It turns

the convection blower on and off, varies the speed of the

convection blower and will shut down appliance if internal

heat exceeds set temperature.

21. Vacuum Switch
The vacuum switch is located on the right side of the

appliance under the feed motor behind right side panel and

connects to the drop tube with a hose. This switch turns

the feed system on when vacuum is present in the firebox.

The vacuum switch is a safety device to shut off the feed

motor if the exhaust or the heat exchanger system is dirty,

plugged or if the firebox door is open.
22. Wall Control Thermostat
The appliance is designed to run on a custom designed .

volt DC thermostat wall control. It will not operate on any

other wall control. Refer to the instructions supplied with

the appliance located in the component pack.
23. Wiring Schematic for Power Supply

See Figure 43.1 below.

24. Wiring Schematic for Control Board

See Figure 43.2 below.

#

Description

1

Combustion Blower

2

Auto-Clean System

3

Feed/Auger Motors

4

Hopper/Door Switches

5

Auger/Auto-Clean/Vacuum

Switches

6

Low Fuel

#

Description

7

Thermostat Wall Control

8

Combustion Blower (feedback)

9

Firepot Thermocouple

10

Drop Tube Thermocouple

n/a Not Used
11

Convection Blower (feedback)

#

Description

12

Igniter

13

AC Power In for Igniter

14

Convection Blower Power

15

Overheat Sensor (Snap Disc)

16

DC Power In from Power Supply

17

1 Volt Battery Back-up

Figure 43.2 - Control Board

Figure 43.1 - Power Supply

Input Line Voltage

AC out to Control

Board

15V DC out to

Control Board

Fuse

15A 250V

Power Supply shown with cover removed

Input Line

Voltage

Heat sinks are taped to cover for shipping. Slowly lift cover

and cut the tape holding them in place and then you can

remove the cover.

17

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

n/a

Fuse 15A 230V,

under the cover

Fuse 15A 230V,

under the cover