Quadra-Fire MTVERNON-AE-MBK User Manual

Page 27

Advertising
background image

R

R

R

August 13, 2009

7034-106F

Page 7

Mt. Vernon Pellet Stove (AE)

1. Start-Up Cycle
During this cycle:

Igniter turns on for 90 seconds to heat up the air in the

firepot

• C

ombustion blower starts

• V

acuum switch comes on

• Feed motor turns on adding fuel to the firepot and the

appliance waits for the fire to start

The duration of start-up depends on the type and quality

of fuel used. It is normal to see some smoke during the

ignition process as moisture evaporates and the fuel lights.

The smoke will stop once the fire starts.

K. Ignition Cycles

The appliance engine is controlled by the digital thermostat

wall control. The digital display on the wall control will tell

you what your appliance is doing in the upper left corner

(System Status). Figure 27.1.

READY

73

Set at: 73

12:30 PM

HEAT OUTPUT

MENU

System Status

Every time the thermostat calls for heat, the appliance steps

through five cycles:

1

Start-Up Cycle

4

Shutdown Cycle

2

Soft-Start Cycle

5

Auto-Clean Cycle

3

Heating Cycle

The duration and characteristics of these cycles may be dif-

ferent with each type of fuel selected.

Figure 27.1

WARNING! RISK OF FIRE!
Do

NOT operate appliance:

• With appliance door open
• With firepot floor open
• With ash pan removed

2. Soft Start Cycle (SS-Low / SS-Med)
Once the fire is lit:
• T

he appliance moves into the low soft-start cycle as it

continues to build the fire

• More fuel will be added
• As the fire builds, the appliance will change to medium

soft-start mode

• The heating cycle begins

3. Heating Cycle ( Auto / Man - L, ML, M, MH, H)
There are two choices in the Automatic / Manual menu of

how your appliance will operate:
Automatic Mode

• T

he wall control will turn the heat output level up or down

depending on how far the room temperature is from the

desired temperature

The digital display will read AUTO:M, i.e. automatic-me-

dium level

• As the room temperature approaches the desired tem-

perature, the appliance will turn down to lower settings

• When the home reaches your set temperature, the appli-

ance will go into the shutdown cycle

Manual Mode
• Set the heat output setting from the main screen

The right bottom button will read HEAT OUTPUT

• You can operate the appliance from any of the 5 levels
• On the lowest level (MAN: L) the appliance will stay on

longer, burn less fuel per hour, and will take longer to

bring the home up to your desired temperature

• On the highest setting (MAN:H) the appliance will burn

more fuel per hour, and bring your home up to tempera-

ture more quickly

In Manual mode the heat output does not change but

will stay at the setting you chose until the comfort level

is reached (meaning the thermostat has been satisfied).

Turn to OFF to stop operation.

4. Shutdown Cycle
Once your home has reached your set temperature:
• A

ppliance will stop feeding fuel and allow the fire to dimin-

ish

Convection blower will continue to run until the appliance

cools to appropriate temperature

• Appliance will begin the auto-clean cycle