13. Soot and Fly Ash: Formation & Need for Removal

in Exhaust Venting System.

Frequency:

Prior to each burn season and after pro-

longed shut down.

By:

Qualified Service Technician/Homeowner

The products of combustion will contain small particles

of fly ash. The fly ash will collect in the exhaust venting

system and restrict the flow of the flue gases. At start-up

if there is incomplete combustion, or if there is a shut-

down or incorrect operation of the appliance it will lead

to some soot formation. This will collect in the exhaust

venting system.
The venting system may need to be cleaned at least

once a year or more often depending upon the quality

of your fuel or if there is a lot of horizontal pipe sec-

tions. Ash will build up more quickly in the horizontal

sections.

14. Preparing Firebox for Non-Burn Season

Frequency:

Yearly at end of burn season

By:

Homeowner

a. The appliance must be in complete shutdown and

allow the appliance to completely cool down.

b. Remove all ash from firebox and vacuum thor-

oughly.

c. Paint all exposed steel, including cast-iron. Use

the Touch-Up paint supplied with the appliance or

purchase paint from your local dealer. You must

use a high-temperature paint made specificially for

heating appliances.

d. Cleaning the flue at the end of the burn season

will prevent corrosives to build-up and damage the

flue.

e. Outside temperatures should have no affect on

the performance of the appliance under freezing

conditions.