Warning, L* k k m, Mt. vernon pellet stove (ae) – Quadra-Fire MTVERNON-AE-MBK User Manual

Page 8: B. clearances to combustibles (ul and ulc), C. hearth pad requirements (ul and ulc)

Advertising
background image

Page 8

7034-106F

August 13, 2009

R

Mt. Vernon Pellet Stove (AE)

R

R

Straight Back Against Wall

Inches

Millimeters

A

Back Wall to Appliance

2

51

B

Side Wall to Appliance

6

152

Corner Installation

Inches

Millimeters

C

Walls to Appliance

2

51

Vertical Installation

Inches

Millimeters

D

Back Wall to Flue Pipe

3

76

E

Side Wall to Appliance

6

152

F

Back Wall to Appliance

8

203

Installations with:

3 to 3 inch Top Vent Adapter and
3 to 6 inch Offset Adapter Kit

Corner Installation

Inches

Millimeters

G

Side Wall to Flue Pipe

3

76

Alcove Installation

Inches

Millimeters

Minimum Alcove Height

43

1092

Minimum Alcove Side Wall

6

152

Minimum Alcove Width

40

1016

Maximum Alcove Depth

36

914

B. Clearances to Combustibles (UL and ULC)

D

E

F

A

B

*L Exception

for Horizontal Installations:

USA INSTALLATIONS

: A non-combustible floor protec-

tion is recommended extending beneath the flue pipe

when installed with horizontal venting or under the Top

Vent Adapter with vertical installation.
CANADA INSTALLATIONS

: A non-combustible floor

protection extending beneath the flue pipe is required

with horizontal venting or under the Top Vent Adapter with

vertical installation.

Must extend  inches (51mm) beyond each

side of pipe (shaded area)

Fire Risk.
Comply with all minimum clearances to

combustibles as specified.

WARNING

Failure to comply may cause house fire.

NOTE:

Illustrations reflect typical installations and are FOR

DESIGN PURPOSES ONLY.

I

llustrations/diagrams are not drawn to scale.

Actual installation may vary due to individual design

preference.

C

C

G

G

C. Hearth Pad Requirements (UL and ULC)

L*

K

K

M

Use a non-combustible floor protector, extending beneath

appliance and to the front, sides and rear as indicated.

Measure front distance “M” from the surface of the glass

door.

Hearth Pad Requirements

Inches

Millimeters

K

Sides

2

51

L*

Back

2

51

M

Front

6

152

Advertising