9 CHECK AND ADJUSTMENT

7

Collimate target A.

Collimate

A

(Reverse)

8

Press [F6](SET)key.
Repeat the procedures in step

7

and

8

so

that the count of measured times matches to
the one in FACE(1).
* 2),3),4)

The title display will be shown automatically.

[F6]

9

Collimate target B (more than ±10

°

from the

level ) in reverse telescope setting
(FACE(2)). *5)

Collimate

B

(Reverse)

10

Press [F6](SET)key. *1)

[F6]

11

Turn the telescope in normal telescope
setting(FACE(1)).

Turn

telescope

12

Collimate target B.

Collimate

B

(Normal)

13

Press [F6](SET) key. Repeat the procedures
in step

12

and

13

so that the count of

measured times matches to the one in
FACE(2).
Then the display returns to main menu.

[F6]

*1) It is able to get the average value from 1 to 10 measurements. To get the average, repeat the

procedures in steps

4

,

5

or

9

,

10

. The measured times is counted in the second line of display.

*2) The compensation values of 1) Error of vertical axis (X,Y tilt sensor offset),

2) Collimation error, and 3) Error of vertical angle 0 datum will be set and memorized internally.

*3) The operating procedure steps to set compensation value of 4) Error of horizontal axis.
*4) Pressing [F1](SKIP) key enables to set next step without changing the last compensated value.
*5) Pressing [F1](SKIP) key makes end of setting without changing compensation value.

FACE 2

V:270°04'20"

SKIP SET

LEVEL±0

5/5

(B)HORIZONTAL Axis

FACE 2

V:270°04'20"

SKIP SET

LEVEL±10°

/0

FACE 2

V:270°04'20"

SKIP SET

LEVEL±10°

/5

FACE 1

V: 69°58'30"

SKIP SET

LEVEL±10°

5/5

Complete