Topcon GTS-823A User Manual

Page 114

Advertising
background image

9-15

9 CHECK AND ADJUSTMENT

9.9

Inspection and Adjustment of Optic Axis for Auto -Tracking

Activates auto tracking to the prism.
Confirm if the center of telescope reticle and the center of the prism is coincided.
Any error between them requires adjustment according to the following procedure.

l

Position a prism around 0 in horizontal and more than100m (328ft) apart from the GTS-820A
series.

l

Take care not to be interrupted the optical path during measurement.

Operating procedure

Operation

Display

1

Level the instrument properly with the plate
level and press the [F5] key from main menu.

[F5]

2

Press the [F6] key to get the next page.

[F6]

3

Press the [F2] key to select the adjustment of
tracking axis.

[F2]

4

Operate H / V jog shuttle to collimate the

center of

prism

Collimate

5

Press the [F6](MEAS) key.
The measurement starts.

[F6]

6

After the measurement, press the [F1](TURN)
key.
The instrument and telescope will turn
automatically.

[F1]

7

Operate H / V jog shuttle to collimate the
center of prism

Collimate

Prism center

Telescope reticle center

Centers of prism
and telescope is shifted

Normal position

Prism center

Telescope reticle center

Adjustment

F1 V0/Axis (Measurement)

F2 V0/Axis (Constant list)

F3 Date Time

F4 Instrument constant

Adjustment

F1 FRQ check

F2 Adj Tracking Axis

Adj Tracking Axis

[1/2]

>Sight the prism !!

TURN MEAS

Adj Tracking Axis

Wait

Adj Tracking Axis

[2/2]

>Sight the prism !!

TURN MEAS