5 PROGRAM MODES

5.2

Retaining a Coordinate (STORE- NEZ)

Suppose the instrument P0 moves to P1, P2, P3, etc. and the coordinate at P1, P2, P3 etc., last point
will be retained in the memory, after moving, as from the origin point.

l

Set the coordinate value of instrument point P

0

and set the direction angle from instrument point P0

toward known point A

.

Operating procedure

Operation

Display

1

Press [F2](STORE) key.

[F2]

2

Press [F1](Store NEZ) key. *1)

[F1]

3

Collimate target P1 prism which the
instrument moves.

Collimate

P1

4

Press [F1](MEAS) key.
Measuring will start.

[F1]

Horizontal distance and horizontal angle are
shown.

Origin (0,0,0)

P

3

P

2

P

1

N

Direction angle

Known point A

E

Inst. point P

0

Programs

F1 BS p 4/7

F2 STORE p

F3 REM p

F4 MLM p MORE

Retaining Coordinate

1.Store NEZ

2.Recall NEZ

Store NEZ

HR : 120°30'40"

HD : m

MEAS HT SET

Store NEZ

HR : 100°10'20"

HD *

<

m

MEAS SET

Store NEZ

HR : 100°10'20"

HD * 123.456 m

MEAS

SET