3 remote elevation measurement (rem), 3 remote elevation measurement (rem) -5 – Topcon GTS-823A User Manual

Page 63

Advertising
background image

5-5

5 PROGRAM MODES

5.3

Remote Elevation measurement (REM)

To obtain elevation of the point at which setting the target prism is not possible, place the prism at any
point on the vertical line from the target then carry out REM procedure as follows.

1) With prism height (h) input (Example :h=1.5m)

Operating procedure

Operation

Display

1

Press [F3](REM) key.

[F3]

2

Press [F1](YES) key.

[F1]

3

Enter prism height, press [ENT] key.

Enter

P.HT

[ENT]

4

Collimate prism .

Collimate

P

5

Press [F1](MEAS) key.
Measuring starts.

[F1]

Target K

Prism P

Prism height

G

Instrument

VD

Programs

F1 BS p 4/7

F2 STORE p

F3 REM p

F4 MLM p MORE

REM

Prism height

1.YES

2.NO

REM

(1)Prism Height

P.h : m

EXIT BS

REM

(2)Horizontal Distance

HD : m

MEAS SET

REM

(2)Horizontal Distance

HD * < m

MEAS SET

Advertising