4-6

4 STANDARD MEASUREMENT MODE

4.2.4 Distance Measurement (Single/N-times Measurement)

When presetting the number of times, the instrument measures the distance as the setting times and
the average distance will be displayed.
When presetting the number of times as 1, it does not display the average distance, because of single
measurement. It has been set at single measurement at factory.

1)Setting the number of times

Confirm the angle measurement mode.

2)Measuring Method

Confirm the angle measurement mode.

Operating procedure

Operation

Display

1

Press [F1](SD) or [F2](HD) key.

2

Press [F6](

) key to get the function page as

2.

[F2]

[F6]

3

Press [F3](MEAN) key.

[F3]

4

Input the setting the number of times, and
press [ENT] key. *1)
[Example] 4 times
N-times measurement starts.

[F4][ENT]

Operating procedure

Operation

Display

1

Collimate the center of the prism.

Collimate

2

Select the measurement mode by pressing
[F1](SD) or [F2](HD) key.
Example: Horizontal distance
N-times measurement starts.

[F2]

V : 90

°10'20"

HR: 120

°30'40"

SD HD NEZ 0SET HOLD P1

V : 90

°10'20"

HR: 120

°30'40" PSM 0.0

HD: PPM 0.0

VD: (m) F.R

MEAS MODE VH SD NEZ P1

REC SO MEAN m/ft P2

Average times

N:0

EXIT BS

V : 90

°10'20"

HR: 120

°30'40" PSM 0.0

HD: < PPM 0.0

VD: (m) *F.N

REC SO MEAN m/ft P2

V : 90

°10'20"

HR: 120

°30'40"

SD HD NEZ 0SET HOLD P1

V : 90

°10'20"

HR: 120

°30'40" PSM 0.0

HD: PPM 0.0

VD: (m) F.N

MEAS MODE VH SD NEZ P1